水(shui)(shui)泵(beng)专用节电(dian)设备(bei)(bei)是专门用于(yu)水(shui)(shui)泵(beng)类节电(dian)控制(zhi)的(de)(de)(de),集电(dian)力(li)(li)电(dian)子(zi)技(ji)术、智(zhi)能(neng)控制(zhi)技(ji)术于(yu)一身的(de)(de)(de)高科技(ji)节能(neng)产品,它具(ju)有(you)优异的(de)(de)(de)调节性能(neng)和节电(dian)效果。本(ben)节电(dian)设备(bei)(bei)可(ke)在(zai)保持阀(fa)门全部打开的(de)(de)(de)情况下,以(yi)水(shui)(shui)泵(beng)输(shu)出(chu)(chu)流量(liang)或(huo)(huo)压力(li)(li)为控制(zhi)对象,用户(hu)可(ke)以(yi)根据实际需要水(shui)(shui)泵(beng)输(shu)出(chu)(chu)流量(liang)或(huo)(huo)压力(li)(li)的(de)(de)(de)给(ji)定值(zhi)来(lai)进行调节。当水(shui)(shui)池(chi)液(ye)位(wei)变化时,节电(dian)设备(bei)(bei)自(zi)动跟(gen)踪水(shui)(shui)泵(beng)输(shu)出(chu)(chu)的(de)(de)(de)流量(liang)或(huo)(huo)压力(li)(li),通过内(nei)部控制(zhi),满足用户(hu)给(ji)定值(zhi)的(de)(de)(de)佳状态,保护水(shui)(shui)泵(beng)迅速无级平(ping)滑地(di)自(zi)动调节在(zai)用户(hu)要求流量(liang)或(huo)(huo)压力(li)(li)下的(de)(de)(de)转速状态,形成闭环路自(zi)动控制(zhi)系统,以(yi)达到节能(neng)降耗(hao)的(de)(de)(de)目的(de)(de)(de)。
1、用(yong)途:DFK水泵(beng)专用(yong)保护控(kong)制(zhi)器采用(yong)当(dang)今世界先(xian)进水平的(de)高(gao)新技术生产而(er)成,可以本(ben)型泵(beng)进行全自(zi)动保护(过载、缺相、短路(lu)、渗(shen)漏等保护),实行泵(beng)的(de)无人看管,自(zi)动运行及信(xin)号输(shu)出,且具有(you)手动和(he)自(zi)动两种控(kong)制(zhi)方式可选择。
2、使用条(tiao)件(jian):(1)周围高气(qi)(qi)(qi)温(wen)(wen)(wen)≤+40℃,≥-5℃,且(qie)24h平均(jun)温(wen)(wen)(wen)度不(bu)超过+35℃;(2)安装(zhuang)地点(dian)海(hai)拔不(bu)超过200m;(3)空气(qi)(qi)(qi)月平均(jun)大湿度百分之≤90(平均(jun)气(qi)(qi)(qi)温(wen)(wen)(wen)25℃时);(4)周围空气(qi)(qi)(qi)无(wu)爆炸危(wei)险的(de)介(jie)(jie)质(zhi),且(qie)介(jie)(jie)质(zhi)中无(wu)足以腐蚀金属和破坏绝缘的(de)气(qi)(qi)(qi)体及导(dao)电尘埃(ai)(污(wu)染(ran)等级3级)。
3、种类:本型(xing)控制(zhi)器有一(yi)(yi)控一(yi)(yi)、二控二(一(yi)(yi)用一(yi)(yi)备)、一(yi)(yi)控三(二用一(yi)(yi)备)三种。
直接(jie)启(qi)动(dong)控(kong)制柜(ju)(工频启(qi)动(dong)控(kong)制柜(ju))控(kong)制回路中,既设自(zi)动(dong)控(kong)制亦有手动(dong)控(kong)制,还具备过压、过流、欠压、缺相(xiang)保护及事故报苦功能,使用前,须按(an)电气原理图复核后(hou)接(jie)线,按(an)照(zhao)电动(dong)机实际(ji)要求调整(zheng)相(xiang)应元(yuan)件设定值,然后(hou)起动(dong)。
1、自动操作(zuo):接(jie)(jie)通(tong)电(dian)(dian)(dian)源,电(dian)(dian)(dian)源指(zhi)示(shi)(shi)灯(deng)亮,将转换(huan)开(kai)关转至“自动”位(wei)(wei)(wei)置,检查控(kong)制(zhi)(zhi)(zhi)柜(箱)所控(kong)制(zhi)(zhi)(zhi)的(de)电(dian)(dian)(dian)机是否按液位(wei)(wei)(wei)控(kong)制(zhi)(zhi)(zhi)仪(yi)的(de)指(zhi)令动作(zuo)。当(dang)液位(wei)(wei)(wei)达到控(kong)制(zhi)(zhi)(zhi)液位(wei)(wei)(wei)时(shi),对(dui)应(ying)(ying) 液位(wei)(wei)(wei)指(zhi)示(shi)(shi)灯(deng)发光(guang),相应(ying)(ying)的(de)限位(wei)(wei)(wei)控(kong)制(zhi)(zhi)(zhi)继电(dian)(dian)(dian)器(qi)(qi)常开(kai)触点自动闭合,二次(ci)控(kong)制(zhi)(zhi)(zhi)回路(lu)自动接(jie)(jie)通(tong),电(dian)(dian)(dian)机起动,同时(shi)运行指(zhi)示(shi)(shi)灯(deng)亮。当(dang)水位(wei)(wei)(wei)达到停止(zhi)水位(wei)(wei)(wei)时(shi),对(dui)应(ying)(ying)的(de)指(zhi)示(shi)(shi)灯(deng)发光(guang), 液位(wei)(wei)(wei)测控(kong)仪(yi)的(de)对(dui)应(ying)(ying)限位(wei)(wei)(wei)控(kong)制(zhi)(zhi)(zhi)继电(dian)(dian)(dian)器(qi)(qi)常闭触点断开(kai),二次(ci)控(kong)制(zhi)(zhi)(zhi)回路(lu)开(kai)路(lu),电(dian)(dian)(dian)机停止(zhi)工作(zuo),运行指(zhi)示(shi)(shi)灯(deng)熄灭。
2、手动操作:接(jie)通电源(yuan),电源(yuan)指示灯亮,将转(zhuan)换开关转(zhuan)至“手动”位置 ,按(an)(an)下(xia)起动按(an)(an)钮(niu),电机开始运(yun)转(zhuan),运(yun)行(xing)指示灯亮,按(an)(an)下(xia)”停(ting)止”按(an)(an)钮(niu),电机停(ting)止运(yun)转(zhuan),其运(yun)行(xing)指示灯熄灭。
3、不论采用何种控制方式,当达到限(xian)(xian)水位时,其(qi)超(chao)限(xian)(xian)水位信号触(chu)点接通,二次控制回路失电(dian),使电(dian)机(ji)停止(zhi)运(yun)转,并发出声光报苦信号。在电(dian)机(ji)运(yun)行过(guo)程中如(ru)有事故出现,事故指示灯亮,电(dian)铃自动报苦,这时,按(an)下停止(zhi)按(an)钮,迫使电(dian)机(ji)停止(zhi)工作。